Maintenance Windows
Silence incidents and alerts during planned maintenance and deployments.
Maintenance windows suppress incidents, pages and alert notifications during planned downtime. Monitors keep checking during maintenance and their status reflects reality, but no incident opens and alert rules don’t fire for the monitors the window covers.
Create a maintenance window
- Open Settings > Maintenance in the app and tap Schedule maintenance (web dashboard: Observe > Maintenance)
- Title: Descriptive name (e.g., “Database migration”)
- Description: Optional details (e.g., “Upgrading PostgreSQL from 15 to 16”)
- Start and End: when maintenance begins and completes (the end must be after the start)
- Monitors: select specific monitors of the project, or none for all of them
- Save
From a monitor’s push notification, Schedule maintenance opens the form for that monitor.
With the API (owners, admins and members):
curl -X POST https://api.incidion.dev/api/v1/projects/$PROJECT_ID/maintenance/ \
-H "Authorization: Bearer $ACCESS_TOKEN" \
-H "Content-Type: application/json" \
-d '{
"title": "PostgreSQL 16 migration",
"description": "Primary and replica restart",
"starts_at": "2026-10-15T22:00:00Z",
"ends_at": "2026-10-15T23:30:00Z",
"monitors": ["'$DB_MONITOR_ID'", "'$API_MONITOR_ID'"]
}'
GET .../maintenance/?status=active|scheduled|completed lists windows; PATCH and DELETE .../maintenance/{id}/ change or remove one. This also lets a deploy script open a window right before it starts.
Maintenance window status
| Status | Meaning |
|---|---|
| Scheduled | Start time is in the future |
| Active | Current time is between start and end |
| Completed | End time has passed |
Scope
- All monitors: leave the monitors list empty. The window covers every monitor of the project, incidents without a monitor, and the project’s log and metric alert rules.
- Specific monitors: select one or more monitors of the project; only those are silenced.
If you only care about database maintenance, select only the database-related monitors. Other monitors still open incidents.
What gets silenced
During an active maintenance window:
- No incidents are opened for the covered monitors, even if they go down
- No pages go out for incidents of covered monitors (or, for a window without monitors, for any incident of the project); paging starts when the window ends if the incident is still unacknowledged
- Alert rules don’t fire for covered monitors; log and metric rules are silenced by a window that covers the whole project
- Monitor status updates normally: the monitor still checks and shows that it is in maintenance
- Existing incidents remain: incidents opened before the window aren’t closed
When the window ends (or is deleted) and a covered monitor is still down, Incidion opens its incident then, so the outage is not missed.
Edit, extend or end early
Open the window and change its end time: later to extend it, now to end it early. Alerts and incidents resume as soon as the window has ended.
Canceling
Delete the window. Monitoring and alerting continue as if it never existed.
Common scenarios
Database upgrade
Title: PostgreSQL 15 → 16 Migration
Start: 2026-10-15 22:00 UTC
End: 2026-10-15 23:30 UTC
Monitors: db-primary, db-replica, api
The API and database monitors are silenced for 1.5 hours. Web and mobile app monitors alert normally so you know if the API is reachable during migration.
Full deployment
Title: Production API Release v2.0
Start: 2026-10-16 03:00 UTC
End: 2026-10-16 03:15 UTC
Monitors: none (all monitors of the project)
All monitors of the project are silenced for 15 minutes during the release.
Overlapping windows
You can have multiple maintenance windows. A monitor is silenced while any window that covers it is active.
Status pages
Status pages show maintenance automatically: a window that has not ended is listed as scheduled or in progress with the components it affects, and those components show Maintenance while it is active. You don’t need to post an incident for planned work.
Notification about maintenance
Incidion doesn’t notify team members when you create a maintenance window. Tell your team in your usual channel.
Best practices
- Buffer time: Add 5-10 minutes before and after the actual work for preparation and verification
- Specific scope: Only silence what’s changing
- Document changes: Use the description field to explain what’s being done
- Coordinate: If multiple teams are deploying, use one maintenance window with a clear description
Emergency maintenance
For unplanned work you want to keep from paging:
- Create a maintenance window starting now
- Select the affected monitors
- Save
This immediately silences the selected monitors. End or delete the window when the work is done.